TDK-Lambda Genesys 3U 10kW
Alimentation DC programmable rack 3U, 10kW, jusque 1500V et 1000A , entrée triphasé
Puissance: 10kW.
Tension: jusqu'à 0-1500 V DC (selon modèle).
Courant: jusqu'à 0-1000 A DC (selon modèle).
Entrée triphasé 400V AC.
Interfaces RS-232 et RS-485 en standard.
Interfaces de communication et de programmation (Optionnelles): GPIB (compatible SCPI, programmation et interface maître pour le montage multi appareils), LAN (compatible LXI), USB, analogique isolée (programmation tension (0-5V & 0-10V) ou courant (4-20mA)), RS-485 esclave pour montage multi appareils.
Produit à configuration (gamme de courant et tension, et interfaces de communication/programmation), nous consulter.
Genesys™ 3U series
Programmable 3U Rack Mount power supply
Genesys 3 U 10000 W Range | |||||||||||||||||||||||
Models | Gen 7.5-1000 | Gen 10-1000 | Gen 12.5-800 | Gen 20-500 | Gen 25-400 | Gen 30-333 | Gen 40-250 | Gen 50-200 | Gen 60-167 | Gen 80-125 | Gen 100-100 | Gen 125-80 | Gen 150-66 | Gen 200-50 | Gen 250-40 | Gen 300-33 | Gen 400-25 | Gen 500-20 | Gen 600-17 | Gen 800-12.5 | Gen 1000-10 | Gen 1250-8 | Gen 1500-6.7 |
Power (W) | 7.5 kW | 10 kW | 10 kW | 10 kW | 10 kW | 10 kW | 10 kW | 10 kW | 10 kW | 10 kW | 10 kW | 10 kW | 9.9 kW | 10 kW | 10 kW | 9.9 kW | 10 kW | 10 kW | 10.2 kW | 10 kW | 10 kW | 10 kW | 10 kW |
Voltage (V DC) | 0-7.5 V | 0-10 V | 0-12.5 V | 0-20 V | 0-25 V | 0-30 V | 0-40 V | 0-50 V | 0-60 V | 0-80 V | 0-100 V | 0-125 V | 0-150 V | 0-200 V | 0-250 V | 0-300 V | 0-400 V | 0-500 V | 0-600 V | 0-800 V | 0-1000 V | 0-1250 V | 0-1500 V |
Current (A DC) | 0-1000 A | 0-1000 A | 0-800 A | 0-500 A | 0-400 A | 0-333 A | 0-250 A | 0-200 A | 0-167 A | 0-125 A | 0-100 A | 0-80 A | 0-66 A | 0-50 A | 0-40 A | 0-33 A | 0-25 A | 0-20 A | 0-17 A | 0-12.5 A | 0-10 A | 0-8 A | 0-6.7 A |
- Highest Power Density 10/15kW in 3U
- High Current up to 1000ADC
- Wide Range of popular worldwide Three Phase AC Inputs
- Power Factor 0.88 (Passive Correction on all Inputs)
- Output Voltage up to 1500V. Current up to 1000A
- Built in RS-232 & RS-485 Interface standard
- Parallel Current Summing
- Optional Interfaces: USB. LXI compliant LAN. IEEE488.2 SCPI Multi-Drop. Isolated Analog Interface
- Last Setting Memory; Front Panel Lockout
- Advanced Parallel reports total current up to four identical units
- Global Commands for Serial RS-232/RS-485 Interface
- Reliable Encoders for Voltage and Current Adjustment
- Independent Remote ON/OFF and Remote ENABLE/DISABLE
- Reliable Modular and SMT Design
- 19" Rack Mounted for ATE and OEM Applications. zero stack
- Labview™ and LabWindows™ drivers
- Five Year Warranty
- Worldwide Safety Agency Approvals; UL Recognized and CE Mark for LVD and EMC Regulation (208VAC and 400VAC Input)
Applications
Genesys™ power supplies are designed for demanding applications.
Test & Measurement systems using GPIB control save significant costs by incorporating the optional
IEEE Multi-Drop Interface (IEMD) in the Master. Then up to 30 Slaves may be equipped with the less expensive
Optional RS-485 Multi-Drop (MD) interface.
Automated System designers will appreciate new. standard. remote programming features such as
Global commands. Also. new high-speed status monitoring is available for the RS-485 bus as well as optional
LAN (LXI compliant) or USB Interfaces.
Industrial & Military high power systems can be configured with up to four identical units in parallel. up to 60kW.
No space is required above or below each power supply (zero stack). The Master can be configured by the user to
report total current of the combination. Applications include Heaters. Magnets and Laser Diodes.
Aerospace & Satellite Testing systems use the complete Genesys™ Family: 1U 750W Half Rack.
1U 750W or 1500W Full-Rack. 2U 3.3kW and 3U 10/15kW. All are identical in Front Panel. Rear Panel Analog and
Digital Interface Commands. A wide variety of outputs allows testing of many different devices.
Component Device Testing is simplified because of the many user-friendly control options in analog and
digital interfaces. Lamps. capacitors. motors and actuators are typical devices tested.
Medical Imaging and Treatment systems require reliable power. Modular construction. SMT and thoroughly
proven designs assure continuous performance at full rated power.
Semiconductor Processing & Burn-in equipment designers appreciate the wide variety of worldwide Inputs and
Outputs from which to select depending on application. Selectable Safe and Auto Re-start protects loads and process
integrity. Typical applications include Magnets. Filaments and Heaters.
GenesysTM Power Parallel and Series Configurations
- Parallel operation - Master/Slave:
- Active current sharing allows up to four identical units to be connected in an auto-parallel configuration for four times the output power.
- In Advanced Parallel Master/Slave Mode. total current is programmed and reported by the Master. Up to four supplies act as one.
- Series operation
- Up to two units may be connected in series to increase the output voltage or to provide bipolar output. (Max 600V to Chassis Ground).
Remote Programming via RS-232 & RS-485 Interface
Standard Serial Interface allows daisy-chain control of up to 31 power supplies on the same communication bus with built-in RS-232 & RS-485 Interface with or without Multi-Drop option.
Programming Options (Factory installed)
- New IEEE Multi-Drop Interface
• Allows IEEE Master to control up to 30 (Multi-Drop equipped) slaves over RS-485 daisy-chain
• Only the Master needs be equipped with IEEE Interface
• IEEE 488.2 SCPI Compliant
• Program Voltage • Program Current
• Measure Voltage • Measure Current
• Over Voltage setting and shutdown • Current Foldback shutdown
• Error and Status Messages
- New Multi-Drop Slave Option
• Slaves need to be equipped with the MD Slave (RS-485) option
- Isolated Analog Programming
• Four Channels to Program and Monitor Voltage and Current.
• Isolation allows operation with floating references in harsh electrical environments.
• Choose between programming with Voltage or Current.
• Connection via removable terminal block: Phoenix MC1.5/8-ST-3.81.
• Voltage Programming. user-selectable 0-5V or 0-10V signal.
Power supply Voltage and Current Programming Accuracy ±1%
Power supply Voltage and Current Monitoring Accuracy ±1.5%
• Current Programming with 4-20mA signal.
Power supply Voltage and Current Programming Accuracy ±1%
Power supply Voltage and Current Monitoring Accuracy ±1.5%
- LAN Interface. LXI Compliant to Class C
• Meets all LXI-C Requirements
• Address Viewable on Front Panel
• Fixed and Dynamic Addressing
• Fast Startup
• VISA & SCPI Compatible
• LAN Fault Indicators
• Auto-detects LAN Cross-over Cable
• Compatible with most standard Networks
- USB Interface
• Allows Serial Connection to USB Port on computer
• Serial commands same as (standard) RS-232/RS-485 Interface
Garantie Constructeur Standard | 5 Ans |
755-Format - taille | 3U |
068-Puissance Max. | 10 kW |
057-Tension max. de sortie | 0-7.5 à 0-1500 V DC (selon modèle, voir les options) |
058-Courant max. de sortie | 0-6.7 à 0-1000 A DC (selon modèle, voir les options) |
056-Nombre de sorties | Simple |
717-Programmable | Oui |
501-Interfaces de programmation | Analogique | RS-232 | USB | GPIB |
055-Mode de fonctionnement (Type) | Mode série | Mode parallèle | Mode maître/esclave |
621-Ondulation et bruit | 20-140 mV rms (ripple); 60-1400 mV rms (noise) |
En Stock | Non |
035-Dimensions (HxLxP) (mm) | 133(3U)x482.6(Rack)x564 mm |
013-Poids Net | 43 kg |
- Fiches techniques